Droplet oscillation test case


A water droplet in air with diameter 0.6 mm is set into oscillating motion. The graphs shows the velocity of the liquid near the apex. In the absence of spurious currents and capillary waves, one expects a smooth solution following the reference solution. This test case does not use the Momentum Conserving formulation.